Kit de medidor de conductividad sin cable portátil MP-4

Kit de medidor de conductividad sin cable portátil MP-4
# de producto: HMP4EP
Precio final Contacto Hach
Llamar para consultar fecha de envío

Simple, robust design allows for rapid testing of conductivity, resistivity, Total Dissolved Solids (TDS), and temperature.

Work without probes, allowing rapid testing of pH, ORP (Oxidation Reduction Potential)/Redox, conductivity, resistivity, Total Dissolved Solids (TDS) and temperature. The instruments use integrated sample cups for efficient high throughput testing vs. external probes.

Probe-free meter enables single-handed operation for high-throughput testing or spot checking

Easy one-button operation - just fill the sample cup and push a parameter key to take a measurement.

Achieve reliable readings without frequent calibration

Typical calibration frequency ranges from every two weeks to monthly, depending on individual testing needs. To calibrate, simply press one button and adjust the instrument to the standard's value.

Auto shut-off extends battery life to more than 100 hours or approximately 5000 tests for reliable portable use

MP Meters deliver high performance with a superior accuracy of ±1% due to an advanced four-electrode conductivity cell technology, a unique replaceable pH/ORP sensor, and powerful microprocessor-based circuitry. Additionally, three pre-programmed common salt profiles in every instrument provide unsurpassed accuracy for conductivity, resistivity, and TDS measurements across a wide variety of sample matrices.

Fully automatic temperature compensation is also provided in these instruments. Users may even adjust the temperature compensation or disable the feature for specific applications. When measuring solution types not contained in the microprocessor, a user-adjustable conductivity/TDS conversion ratio gives greater measurement accuracy.

Essentials Package includes MP-4 meter, field case, conductivity standards (50 mL each), TDS standard (50 mL), and user manual

An auto-shutoff maximizes battery life to more than 100 hours (~5000 tests). In addition to longer operation time, MP Meters maintain data integrity thanks to a non-volatile microprocessor that backs up measurement data and retains calibration and memory data, even during a battery change. MP Meters are also waterproof, buoyant, and fully operational after immersion up to 1 meter (3 feet).

Contenido de la caja

Includes: MP-4 meter, field case, conductivity standards (50 mL each), TDS standard (50 mL), and user manual

Especificaciones

¿Kit?: Si
Capacidad: Capacidad de la célula 5 mL (0,2 oz)
Característica especiales: Essential package
Compensación de la temperatura: Automatic 0 – 71 °C (32 – 160 °F)
  Automático (32 - 160 °F)
Contenido de la caja: Includes: MP-4 meter, field case, conductivity standards (50 mL each), TDS standard (50 mL), and user manual
Dimensiones (A x A x P): 64 mm x 69 mm x 196 mm
Exactitud de la Conductividad: Conductividad, TDS, resistividad:
± 1 % de la lectura
Exactitud de la temperatura: 1 % de lectura
Fuente de alimentación: Baterias (ver requerimientos de baterias)
Garantía: 12 meses
Kit Option: Kit
Length: 196 mm
Modelo: MP-4
Pantalla: Pantalla de cristal líquido (LCD) de 4 dígitos
Parámetro: Conductividad, TDS, resistividad y temperatura
Peso: 0,352 kg
Pilas/baterías requeridas: 1, 9V
Protección de la carcasa (IP): IP67 / NEMA 6
Rango de medición de la conductividad: 0 - 9999 µS/cm 10 - 200 mS/cm en 5 rangos automáticos
Rango de medición de Resistividad: 10 KΩ - 30 MΩ
Rango de medición de TDS: 0 - 9999 ppm 10 - 200 ppt en 5 rangos automáticos
Rango de medición de Temperatura: De 0 a 71 °C (de 32 a 160°F)
Rango de Temperatura de operación: 0 - 55 °C
Resolución: 0,01 (<100 KΩ)
  0,01 (<100 ppm)
  0,1 (<1000 KΩ)
  0,1 (>1 MΩ)
  1 % de la lectura
Resolución de la Conductividad: 0,01 (<100 µS), 0,1 (<1000 µS), 1,0 (<10 mS), 0,01 (<100 mS), 0,1 (<200 mS)
Resolución de temperatura: 0,1 °C/F
Resolución TDS 2: 0,1 (<1000 ppm)
Resolución TDS 3: 1,0 (<10 ppt)
Resolución TDS 4: 0,01 (<100 ppt)
Resolución TDS 5: 0,1 (<200 ppt)
Vida útil de la batería: (5000 lecturas)